| Product Overview | | |
LOPH1040-Kit-Com is a 10.4" sunlight readable LCD module. The module consists of a Hydis HV104X01-100 TFT color LCD panel and a I-Tech VHB (very high brightness) backlight. The module is in a universal package that is the standard for I-Tech’s 10.4" sunlight readable LCD modules.
At a backlight power of 19 Watts, the LM191-104X01 module delivers a screen luminance of about 1,550 Cd/m2 (nits). At this brightness level, the display is highly readable under bright ambient lighting, including direct outdoor sunlight. Also, the Hydis HV104X01-100 is an industrial LCD with a wide operating temperature range, from -20 to +70oC, making this LCD module specifically suitable for demanding outdoor applications. |
| |
| Specifications: |
| |
| Parameters |
Typical Value |
Units |
Conditions |
| |
|
|
|
| LCD Screen Luminance |
1,550 |
Cd/m2 |
LCD in OFF state (normally White) |
| Luminance Uniformity |
20% or better |
|
(Note 3) |
| Backlight Power Consumption |
20 |
Watts |
Including driver board losses |
| LCD Contrast Ratio |
~ 200:1 |
|
With LMT BI200A inverter |
| |
~ 600:1 |
|
White vs. Black (measured in the dark along the normal direction) |
| Typical Viewing Angles |
| 3:00 directions |
89 |
Degrees |
Contrast ratio ≥ 10 |
| 9:00 directions |
89 |
Degrees |
Contrast ratio ≥10 |
| 6:00 direction |
89 |
Degrees |
Contrast ratio ≥10 |
| 12:00 direction |
89 |
Degrees |
Contrast ratio ≥10 |
| LCD Screen Chromaticity (x, y) |
| White |
(0.329, 0.363) |
|
Measured at the normal direction |
| Red |
(0.600, 0.352) |
|
Measured at the normal direction |
| Green |
(0.314, 0.550) |
|
Measured at the normal direction |
| Blue |
(0.149, 0.149) |
|
Measured at the normal direction |
| Response Speed |
| Rise time + Fall time |
28 |
msec |
Luminance transition, 10% - 90% for
rise time, 90% - 10% for fall time |
| LCD Module Weight |
580 |
Grams |
|
|
| |
Note 1: Please refer to “Hydis HV104X01-100 LCD Specification” for detailed electrical specifications and general precautions.
Note 2: All data is measured at 25o C ± 2oC ambient temperature.
Note 3: Uniformity = (Lmax - Lmin) / (Lmax + Lmin) where Lmax (Lmin) is the maximum (minimum) luminance measured using a 10
mm diameter meter aperture over the LCD active area, except the last 10 mm area from the edges. |
| |
| | |
| | |